Á¦Ç°¼Ò°³
¤ýÀÚ¼¼ÃøÁ¤ÀåÄ¡, IMU, GPS/INS
¤ý°í¼º´É MEMS °ü¼º ¼¾¼­, ½Ã½ºÅÛ ¹× ÅëÇÕ GPS
¤ý°íÃâ·Â ¹«¼± ÁõÆø±â
¤ýGNSS ½Ã¹Ä·¹ÀÌÅÍ, GNSS Test & Software Receiver
¤ýIP Core Á¦Ç°
¤ýÅë½ÅÄÉÀ̺í Æ÷¼³Àåºñ
¤ý½Ç³» À§Ä¡(ÃøÀ§) ÃßÀû ½Ã½ºÅÛ
¤ý¹«¼± µ¥ÀÌÅÍ Àü¼Û ½Ã½ºÅÛ
¤ý¼ö¼Ò ¸ÞÀÌÀú, ¼ö¼Ò ½Ã°è
Product Overall
Active Hydrogen Frequency Standard VCH-1003A
Active Hydrogen Maser VCH-1003M
Active Hydrogen Frequency Standard VCH-1005
Passive Hydrogen Maser VCH-1008 new (in development)
¤ýGPS ½Ã°¢µ¿±âÈ­ Àåºñ
¤ýÃÊÁ¤¹Ð ½Ã°£ ÁÖÆļö Àåºñ
¤ý´ÙÁ߸ðµå¿ë Telemetry ¼Û/¼ö½Å±â
¤ýFilter Connector
  Global Partners
Exclusive Representative Contract
with Global Companies
¼ö¼Ò ¸ÞÀÌÀú, ¼ö¼Ò ½Ã°è > Active Hydrogen Frequency Standard VCH-1005
 
Active Hydrogen Frequency Standard VCH-1005
VCH-1005 Hydrogen Frequency and Time Standard provides the highest frequency stable 5 MHz, 100 MHz and 1 Hz (time scale) output signals with the following characteristics:
Frequency accuracy (factory calibration)

¡¾5x10e-13

Frequency corrector:
resolution
range

1x10e-14
1x10e-10

Frequency stability (Allan variance at 25C¡Æ,
environ-mental effects are excluded)

1 s

10 s

100 s

1000 s

1 day

< 3x10e-13

< 3x10e-14

< 8x10e-15

< 3x10e-15

< 3x10e-15

Phase noise (dB/Hz) (at the 5 MHz output):

10 Hz

100 Hz

1000 Hz

< -125

< -140

< -150

Magnetic sensitiveness, (1/Oersted)

< 2x10e-14

Frequency temperature coefficient, (1/¡ÆC)

< 1x10e-14

Operating temperature range, (¡ÆC)

+5 to +40

Power consumption: 220 V 50 Hz AC (VA)

250

Output signal frequency (MHz): 5, 100
Voltage (rms.) at 50 Ohm load (V): 1¡¾ 0.2
Time scale - 1 Hz pulse, pulse width 20 ¡¾ 10 µs, rise time < 10ns, positive polarity TTL level at 50 Ohm load.
Manual synchronization to external 1 pps TTL signal with 50 ns accuracy.
Full data monitoring and functions control (local or remote through any network) performs by personal computer (not includes in delivery set).
Application software running under Microsoft Windows' 9x, 2000, XP, is applied.
Expecting lifetime - 10 years.